Design, fabrication, and testing of microelectromechanical system spark gap switch based on streamer theory 您所在的位置:网站首页 gap testing Design, fabrication, and testing of microelectromechanical system spark gap switch based on streamer theory

Design, fabrication, and testing of microelectromechanical system spark gap switch based on streamer theory

2024-07-14 14:27| 来源: 网络整理| 查看: 265

0960-1317/32/1/015001 Abstract

In order to realize that the fuze micro system has both high security and miniaturization characteristics, the spark gap research of Micro-Electro-Mechanical System safety system is carried out. So that to solve the safe and reliable function of the spark gap switch under the low power supply voltage (35 V) of the fuze micro system, the gas gap size and electrode radius are shown to significantly affect the gas breakdown voltage using streamer theory. Based on these results, a spark gap switch with triggering electrodes is designed. The triggering electrode gap is 2 渭m and the main electrode gap is 10 渭m. A spark gap switch test circuit is designed based on the RLC circuit. Through finite element simulation, it is verified that the gas breakdown voltage increases nonlinearly with increasing gap size. Pre-breakdown spark gap switches were fabricated based on the surface silicon process and tested. The test results show that the conduction voltage values of the triggering electrode and the main electrode are basically consistent with the simulation and calculation results. The breakdown voltage of the main electrode can be greatly reduced by applying a certain voltage to the triggering electrode, realize the reliable function in the micro fuze system.

Export citation and abstract BibTeX RIS

Previous article in issue Next article in issue Access this article

The computer you are using is not registered by an institution with a subscription to this article. Please choose one of the options below.

Login

IOPscience login

Find out more about journal subscriptions at your site.

Purchase from

Article Galaxy CCC RightFind

Purchase this article from our trusted document delivery partners.

Rent from

Purchase this article on DeepDyve. Opens in new tab

Make a recommendation

To gain access to this content, please complete the Recommendation Form and we will follow up with your librarian or Institution on your behalf.

For corporate researchers we can also follow up directly with your R&D manager, or the information management contact at your company. Institutional subscribers have access to the current volume, plus a 10-year back file (where available).

Please wait… references are loading.


【本文地址】

公司简介

联系我们

今日新闻

    推荐新闻

    专题文章
      CopyRight 2018-2019 实验室设备网 版权所有